HP Array Configuration Utility (hpacucli) works with HP RAID controller cards to configure RAID levels, get RAID information, and action various commands on an array.
Common hpacucli commands
To show the configuration status of entire array:
hpacucli ctrl all show config
To show details of all physical drives related to a single RAID controller (note slot number can be obtained by ctrl all show config command):
ctrl slot=<slot number> pd all show detail # this command will provide you with the serial numbers of the physical drives in the array
To show details of a single physical drive:
hpacucli ctrl slot=<slot number> pd <physical drive number> show detail
[root@nfshead2 ~]# /opt/compaq/hpacucli/bld/hpacucli ctrl slot=1 pd 1e:1:7 show detail
Smart Array P800 in Slot 1
array A
physicaldrive 1E:1:7
Port: 1E
Box: 1
Bay: 7
Status: Failed
Drive Type: Data Drive
Interface Type: SATA
Size: 1 TB
Firmware Revision: HPG6
Serial Number: 9QJ2BVES
Model: ATA GB1000EAFJL
SATA NCQ Capable: True
SATA NCQ Enabled: True
PHY Count: 1
PHY Transfer Rate: 1.5GBPS