Replacing failed disk on Server

From DISI
Revision as of 00:46, 26 January 2021 by Jgutie11 (talk | contribs)
Jump to navigation Jump to search

How to check if Disk failed

Check for the light on disk

Solid Yellow => Fail

Blinking Yellow => Predictive Failure (going to fail soon)

Green => Normal

Replace disk instruction

  • Determine what machine the disk below to
  • Press the red button on the disk to turn it off.
  • Gently pull a little bit out (NOT all the way) and wait for 10 sec until it stops spinning before pulling all the way out.
  • Find replacement with a similar disk with the same specs
  • Carefully unscrew the disk from disk holder (if the disk holder part on the replacement is the same then you don't have to).

Auto-check Disk Machines Python Script

In gimel5, there is a python script that runs every day at 12am through crontab under s_jjg.

The file is located at: /nfs/home/jjg/python_scripts/check_for_failed_disks.py

This script ssh-es into the machines below and runs a command to list the status of database. (Does not include cluster 0 machines)

abacus
      db2
      db3
      db5
n-9-22
      db4
tsadi
      ex1
      ex2
      ex3
      ex4
lamed
      ex5
      ex6
      ex7
      ex8
qof
      ex9
zayin
      exa
n-1-30
      exb
n-1-109
      exc
n-1-113
      exd
shin
      db

How to check if disk is failed or install correctly

On Cluster 0 's machines

1. Log into gimel as root

$ ssh root@sgehead1.bkslab.org

2. Log in as root to the machine that you determined from earlier

$ ssh root@<machine_name>
Example: RAID 3,6,7 belongs to nfshead2

3. Run this command

$ /opt/compaq/hpacucli/bld/hpacucli ctrl all show config
Output Example:
Smart Array P800 in Slot 1                (sn: PAFGF0N9SXQ0MX)
  array A (SATA, Unused Space: 0 MB)
     logicaldrive 1 (5.5 TB, RAID 1+0, OK)
     physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 1 TB, OK)
     physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 1 TB, OK)
     physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 1 TB, OK)
     physicaldrive 1E:1:4 (port 1E:box 1:bay 4, SATA, 1 TB, OK)
     physicaldrive 1E:1:5 (port 1E:box 1:bay 5, SATA, 1 TB, OK)
     physicaldrive 1E:1:6 (port 1E:box 1:bay 6, SATA, 1 TB, OK)
     physicaldrive 1E:1:7 (port 1E:box 1:bay 7, SATA, 1 TB, OK)
     physicaldrive 1E:1:8 (port 1E:box 1:bay 8, SATA, 1 TB, OK)
     physicaldrive 1E:1:9 (port 1E:box 1:bay 9, SATA, 1 TB, OK)
     physicaldrive 1E:1:10 (port 1E:box 1:bay 10, SATA, 1 TB, OK)
     physicaldrive 1E:1:11 (port 1E:box 1:bay 11, SATA, 1 TB, OK)
     physicaldrive 1E:1:12 (port 1E:box 1:bay 12, SATA, 1 TB, OK)
  array B (SATA, Unused Space: 0 MB)
     logicaldrive 2 (5.5 TB, RAID 1+0, OK)
     physicaldrive 2E:1:1 (port 2E:box 1:bay 1, SATA, 1 TB, OK)
     physicaldrive 2E:1:2 (port 2E:box 1:bay 2, SATA, 1 TB, Predictive Failure)
     physicaldrive 2E:1:3 (port 2E:box 1:bay 3, SATA, 1 TB, OK)
     physicaldrive 2E:1:4 (port 2E:box 1:bay 4, SATA, 1 TB, OK)
     physicaldrive 2E:1:5 (port 2E:box 1:bay 5, SATA, 1 TB, OK)
     physicaldrive 2E:1:6 (port 2E:box 1:bay 6, SATA, 1 TB, OK)
     physicaldrive 2E:1:7 (port 2E:box 1:bay 7, SATA, 1 TB, OK)
     physicaldrive 2E:1:8 (port 2E:box 1:bay 8, SATA, 1 TB, OK)
     physicaldrive 2E:1:9 (port 2E:box 1:bay 9, SATA, 1 TB, OK)
     physicaldrive 2E:1:10 (port 2E:box 1:bay 10, SATA, 1 TB, OK)
     physicaldrive 2E:1:11 (port 2E:box 1:bay 11, SATA, 1 TB, OK)
     physicaldrive 2E:1:12 (port 2E:box 1:bay 12, SATA, 1 TB, OK)
  array C (SATA, Unused Space: 0 MB)
     logicaldrive 3 (5.5 TB, RAID 1+0, Ready for Rebuild)
     physicaldrive 2E:2:1 (port 2E:box 2:bay 1, SATA, 1 TB, OK)
     physicaldrive 2E:2:2 (port 2E:box 2:bay 2, SATA, 1 TB, OK)
     physicaldrive 2E:2:3 (port 2E:box 2:bay 3, SATA, 1 TB, OK)
     physicaldrive 2E:2:4 (port 2E:box 2:bay 4, SATA, 1 TB, OK)
     physicaldrive 2E:2:5 (port 2E:box 2:bay 5, SATA, 1 TB, OK)
     physicaldrive 2E:2:6 (port 2E:box 2:bay 6, SATA, 1 TB, OK)
     physicaldrive 2E:2:7 (port 2E:box 2:bay 7, SATA, 1 TB, OK)
     physicaldrive 2E:2:8 (port 2E:box 2:bay 8, SATA, 1 TB, OK)
     physicaldrive 2E:2:9 (port 2E:box 2:bay 9, SATA, 1 TB, OK)
     physicaldrive 2E:2:10 (port 2E:box 2:bay 10, SATA, 1 TB, OK)
     physicaldrive 2E:2:11 (port 2E:box 2:bay 11, SATA, 1 TB, OK)
     physicaldrive 2E:2:12 (port 2E:box 2:bay 12, SATA, 1 TB, OK)
  Expander 243 (WWID: 50014380031A4B00, Port: 1E, Box: 1)
  Expander 245 (WWID: 5001438005396E00, Port: 2E, Box: 2)
  Expander 246 (WWID: 500143800460A600, Port: 2E, Box: 1)
  Expander 248 (WWID: 50014380055E913F)
  Enclosure SEP (Vendor ID HP, Model MSA60) 241 (WWID: 50014380031A4B25, Port: 1E, Box: 1)
  Enclosure SEP (Vendor ID HP, Model MSA60) 242 (WWID: 5001438005396E25, Port: 2E, Box: 2)
  Enclosure SEP (Vendor ID HP, Model MSA60) 244 (WWID: 500143800460A625, Port: 2E, Box: 1)
  SEP (Vendor ID HP, Model P800) 247 (WWID: 50014380055E913E)

On shin

As root

/opt/MegaRAID/storcli/storcli64 /c0 /eall /sall show all
Drive /c0/e8/s18 :
 ================

 -----------------------------------------------------------------------------
EID:Slt DID State  DG     Size Intf Med SED PI SeSz Model            Sp Type 
-----------------------------------------------------------------------------
8:18     24 Failed  0 3.637 TB SAS  HDD N   N  512B ST4000NM0023     U  -    
-----------------------------------------------------------------------------

EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup
DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare
UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface
Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info
SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign
UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded
CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded


Drive /c0/e8/s18 - Detailed Information :
=======================================

Drive /c0/e8/s18 State :
======================
Shield Counter = 0
Media Error Count = 0
Other Error Count = 16
BBM Error Count = 0
Drive Temperature =  32C (89.60 F)
Predictive Failure Count = 0
S.M.A.R.T alert flagged by drive = No


Drive /c0/e8/s18 Device attributes :
==================================
SN = Z1Z2S2TL0000C4216E9V
Manufacturer Id = SEAGATE 
Model Number = ST4000NM0023    
NAND Vendor = NA
WWN = 5000C50057DB2A28
Firmware Revision = 0003
Firmware Release Number = 03290003
Raw size = 3.638 TB [0x1d1c0beb0 Sectors]
Coerced size = 3.637 TB [0x1d1b00000 Sectors]
Non Coerced size = 3.637 TB [0x1d1b0beb0 Sectors]
Device Speed = 6.0Gb/s
Link Speed = 6.0Gb/s
Write cache = N/A
Logical Sector Size = 512B
Physical Sector Size = 512B
Connector Name = Port 0 - 3 & Port 4 - 7 

On ZFS machines

$ zpool status

For instruction on how to identify and replace failed disk on ZFS system. Read here

On Any Raid1 Configurations

Steps to fix a hard drive failure that is in a raid 1 configuration:

The following demonstrates what a failed disk looks like:

 [root@myServer ~]# cat /proc/mdstat 
Personalities : [raid1]
md0 : active raid1 sdb1[0] sda1[2](F)
128384 blocks [2/1] [U_]
md1 : active raid1 sdb2[0] sda2[2](F)
16779776 blocks [2/1] [U_]
md2 : active raid1 sdb3[0] sda3[2](F)
139379840 blocks [2/1] [U_]
unused devices: <none>
 [root@myServer ~]# smartctl -a /dev/sda   
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.18-371.1.2.el5] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
Short INQUIRY response, skip product id
A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options.


 [root@myServer ~]# smartctl -a /dev/sdb  
smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.18-371.1.2.el5] (local build)
Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net
=== START OF INFORMATION SECTION ===
Model Family: Seagate Barracuda 7200.10
Device Model: ST3160815AS
Serial Number: 9RA6DZP8
Firmware Version: 4.AAB
User Capacity: 160,041,885,696 bytes [160 GB]
Sector Size: 512 bytes logical/physical
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: Exact ATA specification draft version not indicated
Local Time is: Mon Sep 8 15:50:48 2014 PDT
SMART support is: Available - device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED

There is a lot more that gets printed, but I cut it out.

So /dev/sda has clearly failed.

Take note of the GOOD disk serial number so I leave that one in when I replace it:

 Serial Number:    9RA6DZP8   

Mark and remove failed disk from raid:

 [root@myServer ~]# mdadm --manage /dev/md0 --fail /dev/sda1   
mdadm: set /dev/sda1 faulty in /dev/md0
[root@myServer ~]# mdadm --manage /dev/md1 --fail /dev/sda2
mdadm: set /dev/sda2 faulty in /dev/md1
[root@myServer ~]# mdadm --manage /dev/md2 --fail /dev/sda3
mdadm: set /dev/sda3 faulty in /dev/md2
[root@myServer ~]# mdadm --manage /dev/md0 --remove /dev/sda1
mdadm: hot removed /dev/sda1
[root@myServer ~]# mdadm --manage /dev/md1 --remove /dev/sda2
mdadm: hot removed /dev/sda2
[root@myServer ~]# mdadm --manage /dev/md2 --remove /dev/sda3
mdadm: hot removed /dev/sda3

Make sure grub is installed on the good disk and that grub.conf is updated:

 [root@myServer ~]# grub-install /dev/sdb   
Installation finished. No error reported.
This is the contents of the device map /boot/grub/device.map.
Check if this is correct or not.
If any of the lines is incorrect, fix it and re-run the script `grub-install'.
This device map was generated by anaconda
(hd0) /dev/sda
(hd1) /dev/sdb

Take note of the which hd partition corresponds with the good disk, ie hd1 in this case.

 [root@myServer ~]# vim /boot/grub/menu.lst  
Add fallback=1 right after default=0
Go to the bottom section where you should find some kernel stanzas.
Copy the first of them and paste the stanza before the first existing stanza; replace root (hd0,0) with root (hd1,0)
Should look like this:
[...]
title CentOS (2.6.18-128.el5)
root (hd1,0)
kernel /vmlinuz-2.6.18-128.el5 ro root=/dev/VolGroup00/LogVol00
initrd /initrd-2.6.18-128.el5.img
title CentOS (2.6.18-128.el5)
root (hd0,0)
kernel /vmlinuz-2.6.18-128.el5 ro root=/dev/
initrd /initrd-2.6.18-128.el5.img

Save and quit

 [root@myServer ~]# mv /boot/initramfs-$(uname -r).img /boot/initramfs-$(uname -r).img.bak   
[root@myServer ~]# mkinitrd /boot/initramfs-$(uname -r).img $(uname -r)
[root@myServer ~]# init 0

Swap the bad drive with the new drive and boot the machine.

Once it's booted:

Check the device names with cat /proc/mdstat and/or fisk -l.
The newly installed drive on myServer was named /dev/sda.

 [root@myServer ~]# modeprobe raid1   
[root@myServer ~]# modeprobe linear

Copy the partitions from one disk to the other:

 [root@myServer ~]# sfdisk -d /dev/sdb | sfdisk --force /dev/sda   
[root@myServer ~]# sfdisk -l => sanity check

Add the new disk to the raid array:

 [root@myServer ~]# mdadm --manage /dev/md0 --add /dev/sda1   
mdadm: added /dev/sda1
[root@myServer ~]# mdadm --manage /dev/md1 --add /dev/sda2
mdadm: added /dev/sda2
[root@myServer ~]# mdadm --manage /dev/md2 --add /dev/sda3
mdadm: added /dev/sda3

Sanity check:

 [root@myServer ~]# cat /proc/mdstat  
Personalities : [raid1] [linear]
md0 : active raid1 sda1[1] sdb1[0]
128384 blocks [2/2] [UU]
md1 : active raid1 sda2[2] sdb2[0]
16779776 blocks [2/1] [U_]
[>....................] recovery = 3.2% (548864/16779776) finish=8.8min speed=30492K/sec
md2 : active raid1 sda3[2] sdb3[0]
139379840 blocks [2/1] [U_]
resync=DELAYED
unused devices: <none>