How to check if Disk failed
On shin
/opt/MegaRAID/storcli/storcli64 /c0 /eall /sall show all
Drive /c0/e8/s18 : ================ ----------------------------------------------------------------------------- EID:Slt DID State DG Size Intf Med SED PI SeSz Model Sp Type ----------------------------------------------------------------------------- 8:18 24 Failed 0 3.637 TB SAS HDD N N 512B ST4000NM0023 U - ----------------------------------------------------------------------------- EID-Enclosure Device ID|Slt-Slot No.|DID-Device ID|DG-DriveGroup DHS-Dedicated Hot Spare|UGood-Unconfigured Good|GHS-Global Hotspare UBad-Unconfigured Bad|Onln-Online|Offln-Offline|Intf-Interface Med-Media Type|SED-Self Encryptive Drive|PI-Protection Info SeSz-Sector Size|Sp-Spun|U-Up|D-Down|T-Transition|F-Foreign UGUnsp-Unsupported|UGShld-UnConfigured shielded|HSPShld-Hotspare shielded CFShld-Configured shielded|Cpybck-CopyBack|CBShld-Copyback Shielded Drive /c0/e8/s18 - Detailed Information : ======================================= Drive /c0/e8/s18 State : ====================== Shield Counter = 0 Media Error Count = 0 Other Error Count = 16 BBM Error Count = 0 Drive Temperature = 32C (89.60 F) Predictive Failure Count = 0 S.M.A.R.T alert flagged by drive = No Drive /c0/e8/s18 Device attributes : ================================== SN = Z1Z2S2TL0000C4216E9V Manufacturer Id = SEAGATE Model Number = ST4000NM0023 NAND Vendor = NA WWN = 5000C50057DB2A28 Firmware Revision = 0003 Firmware Release Number = 03290003 Raw size = 3.638 TB [0x1d1c0beb0 Sectors] Coerced size = 3.637 TB [0x1d1b00000 Sectors] Non Coerced size = 3.637 TB [0x1d1b0beb0 Sectors] Device Speed = 6.0Gb/s Link Speed = 6.0Gb/s Write cache = N/A Logical Sector Size = 512B Physical Sector Size = 512B Connector Name = Port 0 - 3 & Port 4 - 7
Check for the light on disk
Solid Yellow => Fail
Blinking Yellow => Predictive Failure (going to fail soon)
Green => Normal
Replace disk instruction
- Determine what machine the disk below to
- Press the red button on the disk to turn it off.
- Gently pull a little bit out (NOT all the way) and wait for 10 sec until it stops spinning before pulling all the way out.
- Find replacement with a similar disk with the same specs
- Carefully unscrew the disk from disk holder (if the disk holder part on the replacement is the same then you don't have to).
How to check if disk is failed or install correctly
1. Log into gimel as root
$ ssh root@sgehead1.bkslab.org
2. Log in as root to the machine that you determined from earlier
$ ssh root@<machine_name> Example: RAID 3,6,7 belongs to nfshead2
3. Run this command
$ /opt/compaq/hpacucli/bld/hpacucli ctrl all show config
Output Example: Smart Array P800 in Slot 1 (sn: PAFGF0N9SXQ0MX) array A (SATA, Unused Space: 0 MB) logicaldrive 1 (5.5 TB, RAID 1+0, OK) physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 1 TB, OK) physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 1 TB, OK) physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 1 TB, OK) physicaldrive 1E:1:4 (port 1E:box 1:bay 4, SATA, 1 TB, OK) physicaldrive 1E:1:5 (port 1E:box 1:bay 5, SATA, 1 TB, OK) physicaldrive 1E:1:6 (port 1E:box 1:bay 6, SATA, 1 TB, OK) physicaldrive 1E:1:7 (port 1E:box 1:bay 7, SATA, 1 TB, OK) physicaldrive 1E:1:8 (port 1E:box 1:bay 8, SATA, 1 TB, OK) physicaldrive 1E:1:9 (port 1E:box 1:bay 9, SATA, 1 TB, OK) physicaldrive 1E:1:10 (port 1E:box 1:bay 10, SATA, 1 TB, OK) physicaldrive 1E:1:11 (port 1E:box 1:bay 11, SATA, 1 TB, OK) physicaldrive 1E:1:12 (port 1E:box 1:bay 12, SATA, 1 TB, OK) array B (SATA, Unused Space: 0 MB) logicaldrive 2 (5.5 TB, RAID 1+0, OK) physicaldrive 2E:1:1 (port 2E:box 1:bay 1, SATA, 1 TB, OK) physicaldrive 2E:1:2 (port 2E:box 1:bay 2, SATA, 1 TB, Predictive Failure) physicaldrive 2E:1:3 (port 2E:box 1:bay 3, SATA, 1 TB, OK) physicaldrive 2E:1:4 (port 2E:box 1:bay 4, SATA, 1 TB, OK) physicaldrive 2E:1:5 (port 2E:box 1:bay 5, SATA, 1 TB, OK) physicaldrive 2E:1:6 (port 2E:box 1:bay 6, SATA, 1 TB, OK) physicaldrive 2E:1:7 (port 2E:box 1:bay 7, SATA, 1 TB, OK) physicaldrive 2E:1:8 (port 2E:box 1:bay 8, SATA, 1 TB, OK) physicaldrive 2E:1:9 (port 2E:box 1:bay 9, SATA, 1 TB, OK) physicaldrive 2E:1:10 (port 2E:box 1:bay 10, SATA, 1 TB, OK) physicaldrive 2E:1:11 (port 2E:box 1:bay 11, SATA, 1 TB, OK) physicaldrive 2E:1:12 (port 2E:box 1:bay 12, SATA, 1 TB, OK) array C (SATA, Unused Space: 0 MB) logicaldrive 3 (5.5 TB, RAID 1+0, Ready for Rebuild) physicaldrive 2E:2:1 (port 2E:box 2:bay 1, SATA, 1 TB, OK) physicaldrive 2E:2:2 (port 2E:box 2:bay 2, SATA, 1 TB, OK) physicaldrive 2E:2:3 (port 2E:box 2:bay 3, SATA, 1 TB, OK) physicaldrive 2E:2:4 (port 2E:box 2:bay 4, SATA, 1 TB, OK) physicaldrive 2E:2:5 (port 2E:box 2:bay 5, SATA, 1 TB, OK) physicaldrive 2E:2:6 (port 2E:box 2:bay 6, SATA, 1 TB, OK) physicaldrive 2E:2:7 (port 2E:box 2:bay 7, SATA, 1 TB, OK) physicaldrive 2E:2:8 (port 2E:box 2:bay 8, SATA, 1 TB, OK) physicaldrive 2E:2:9 (port 2E:box 2:bay 9, SATA, 1 TB, OK) physicaldrive 2E:2:10 (port 2E:box 2:bay 10, SATA, 1 TB, OK) physicaldrive 2E:2:11 (port 2E:box 2:bay 11, SATA, 1 TB, OK) physicaldrive 2E:2:12 (port 2E:box 2:bay 12, SATA, 1 TB, OK) Expander 243 (WWID: 50014380031A4B00, Port: 1E, Box: 1) Expander 245 (WWID: 5001438005396E00, Port: 2E, Box: 2) Expander 246 (WWID: 500143800460A600, Port: 2E, Box: 1) Expander 248 (WWID: 50014380055E913F) Enclosure SEP (Vendor ID HP, Model MSA60) 241 (WWID: 50014380031A4B25, Port: 1E, Box: 1) Enclosure SEP (Vendor ID HP, Model MSA60) 242 (WWID: 5001438005396E25, Port: 2E, Box: 2) Enclosure SEP (Vendor ID HP, Model MSA60) 244 (WWID: 500143800460A625, Port: 2E, Box: 1) SEP (Vendor ID HP, Model P800) 247 (WWID: 50014380055E913E)