Hpacucli: Difference between revisions

From DISI
Jump to navigation Jump to search
(added command for viewing individual drive status)
Line 32: Line 32:
         PHY Transfer Rate: 1.5GBPS
         PHY Transfer Rate: 1.5GBPS


 
To view information about disk enclosures/JBODs:
hpacucli controller slot=1 enclosure all show detail
Smart Array P800 in Slot 1
  StorageWorks MSA 60 at Port 1E, Box 1, OK
      Fan Status: OK
      Temperature Status: OK
      Power Supply Status: Redundant
      Vendor ID: HP     
      Serial Number: SGA837003N
      Firmware Version: 2.18
      Drive Bays: 12
      Port: 1E
      Box: 1
      Location: External
  Expander 243
      Device Number: 243
      Firmware Version: 2.18
      WWID: 50014380031A4B00
      Port: 1E
      Box: 1
      Vendor ID: HP     
  Enclosure SEP (Vendor ID HP, Model MSA60) 241
      Device Number: 241
      Firmware Version: 2.18
      WWID: 50014380031A4B25
      Port: 1E
      Box: 1
      Vendor ID: HP     
      Model: MSA60         
      SEP: (1) 2.18
      Backplane Module (BPM): (1) 2.06, (2) 2.06
      Fan Control Module (FCM): (1) 1.08, (2) 1.08
      Health Monitor Module (HMM): (1) 1.10, (2) 1.10
      Seven Segment LED Display: (1) 0.10
  Physical Drives
      physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 1 TB, OK)
      physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 1 TB, OK)
      physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 1 TB, OK)
      physicaldrive 1E:1:4 (port 1E:box 1:bay 4, SATA, 1 TB, OK)
      physicaldrive 1E:1:5 (port 1E:box 1:bay 5, SATA, 1 TB, OK)
      physicaldrive 1E:1:6 (port 1E:box 1:bay 6, SATA, 1 TB, OK)
      physicaldrive 1E:1:7 (port 1E:box 1:bay 7, SATA, 1 TB, OK)
      physicaldrive 1E:1:8 (port 1E:box 1:bay 8, SATA, 1 TB, OK)
      physicaldrive 1E:1:9 (port 1E:box 1:bay 9, SATA, 1 TB, OK)
      physicaldrive 1E:1:10 (port 1E:box 1:bay 10, SATA, 1 TB, OK)
      physicaldrive 1E:1:11 (port 1E:box 1:bay 11, SATA, 1 TB, OK)
      physicaldrive 1E:1:12 (port 1E:box 1:bay 12, SATA, 1 TB, OK)
[[Category:Sysadmin]]
[[Category:Sysadmin]]

Revision as of 22:12, 7 September 2018

HP Array Configuration Utility (hpacucli) works with HP RAID controller cards to configure RAID levels, get RAID information, and action various commands on an array.

Common hpacucli commands

To show the configuration status of entire array:

hpacucli ctrl all show config


To show details of all physical drives related to a single RAID controller (note slot number can be obtained by ctrl all show config command):

ctrl slot=<slot number> pd all show detail
# this command will provide you with the serial numbers of the physical drives in the array

To show details of a single physical drive:

 hpacucli ctrl slot=<slot number> pd <physical drive number> show detail
 [root@nfshead2 ~]# /opt/compaq/hpacucli/bld/hpacucli ctrl slot=1 pd 1e:1:7 show detail
 Smart Array P800 in Slot 1
  array A
     physicaldrive 1E:1:7
        Port: 1E
        Box: 1
        Bay: 7
        Status: Failed
        Drive Type: Data Drive
        Interface Type: SATA
        Size: 1 TB
        Firmware Revision: HPG6    
        Serial Number: 9QJ2BVES            
        Model: ATA     GB1000EAFJL     
        SATA NCQ Capable: True
        SATA NCQ Enabled: True
        PHY Count: 1
        PHY Transfer Rate: 1.5GBPS

To view information about disk enclosures/JBODs:

hpacucli controller slot=1 enclosure all show detail
Smart Array P800 in Slot 1
  StorageWorks MSA 60 at Port 1E, Box 1, OK
     Fan Status: OK
     Temperature Status: OK
     Power Supply Status: Redundant
     Vendor ID: HP      
     Serial Number: SGA837003N
     Firmware Version: 2.18
     Drive Bays: 12
     Port: 1E
     Box: 1
     Location: External
  Expander 243
     Device Number: 243
     Firmware Version: 2.18
     WWID: 50014380031A4B00
     Port: 1E
     Box: 1
     Vendor ID: HP      
  Enclosure SEP (Vendor ID HP, Model MSA60) 241
     Device Number: 241
     Firmware Version: 2.18
     WWID: 50014380031A4B25
     Port: 1E
     Box: 1
     Vendor ID: HP      
     Model: MSA60           
     SEP: (1) 2.18
     Backplane Module (BPM): (1) 2.06, (2) 2.06
     Fan Control Module (FCM): (1) 1.08, (2) 1.08
     Health Monitor Module (HMM): (1) 1.10, (2) 1.10
     Seven Segment LED Display: (1) 0.10
  Physical Drives
     physicaldrive 1E:1:1 (port 1E:box 1:bay 1, SATA, 1 TB, OK)
     physicaldrive 1E:1:2 (port 1E:box 1:bay 2, SATA, 1 TB, OK)
     physicaldrive 1E:1:3 (port 1E:box 1:bay 3, SATA, 1 TB, OK)
     physicaldrive 1E:1:4 (port 1E:box 1:bay 4, SATA, 1 TB, OK)
     physicaldrive 1E:1:5 (port 1E:box 1:bay 5, SATA, 1 TB, OK)
     physicaldrive 1E:1:6 (port 1E:box 1:bay 6, SATA, 1 TB, OK)
     physicaldrive 1E:1:7 (port 1E:box 1:bay 7, SATA, 1 TB, OK)
     physicaldrive 1E:1:8 (port 1E:box 1:bay 8, SATA, 1 TB, OK)
     physicaldrive 1E:1:9 (port 1E:box 1:bay 9, SATA, 1 TB, OK)
     physicaldrive 1E:1:10 (port 1E:box 1:bay 10, SATA, 1 TB, OK)
     physicaldrive 1E:1:11 (port 1E:box 1:bay 11, SATA, 1 TB, OK)
     physicaldrive 1E:1:12 (port 1E:box 1:bay 12, SATA, 1 TB, OK)