How to Replace a Failed Disk

From DISI
Revision as of 19:13, 9 September 2014 by Therese (talk | contribs)
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Steps to fix a hard drive failure that is in a raid 1 configuration:

[root@myServer ~]# cat /proc/mdstat Personalities : [raid1] md0 : active raid1 sdb1[0] sda1[2](F) 128384 blocks [2/1] [U_] md1 : active raid1 sdb2[0] sda2[2](F) 16779776 blocks [2/1] [U_] md2 : active raid1 sdb3[0] sda3[2](F) 139379840 blocks [2/1] [U_] unused devices: <none>

To see which disk is failed:

The following demonstrates what a failed disk looks like:

[root@myServer ~]# smartctl -a /dev/sda smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.18-371.1.2.el5] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

Short INQUIRY response, skip product id A mandatory SMART command failed: exiting. To continue, add one or more '-T permissive' options.


[root@myServer ~]# smartctl -a /dev/sdb smartctl 5.42 2011-10-20 r3458 [x86_64-linux-2.6.18-371.1.2.el5] (local build) Copyright (C) 2002-11 by Bruce Allen, http://smartmontools.sourceforge.net

START OF INFORMATION SECTION

Model Family: Seagate Barracuda 7200.10 Device Model: ST3160815AS Serial Number: 9RA6DZP8 Firmware Version: 4.AAB User Capacity: 160,041,885,696 bytes [160 GB] Sector Size: 512 bytes logical/physical Device is: In smartctl database [for details use: -P show] ATA Version is: 7 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Mon Sep 8 15:50:48 2014 PDT SMART support is: Available - device has SMART capability. SMART support is: Enabled

START OF READ SMART DATA SECTION

SMART overall-health self-assessment test result: PASSED

General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 430) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 54) minutes.

SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE

 1 Raw_Read_Error_Rate     0x000f   100   253   006    Pre-fail  Always       -       0
 3 Spin_Up_Time            0x0003   097   097   000    Pre-fail  Always       -       0
 4 Start_Stop_Count        0x0032   100   100   020    Old_age   Always       -       44
 5 Reallocated_Sector_Ct   0x0033   100   100   036    Pre-fail  Always       -       8
 7 Seek_Error_Rate         0x000f   084   060   030    Pre-fail  Always       -       239527837
 9 Power_On_Hours          0x0032   043   043   000    Old_age   Always       -       50308
10 Spin_Retry_Count        0x0013   100   100   097    Pre-fail  Always       -       0
12 Power_Cycle_Count       0x0032   100   100   020    Old_age   Always       -       44

187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 189 High_Fly_Writes 0x003a 100 100 000 Old_age Always - 0 190 Airflow_Temperature_Cel 0x0022 075 061 045 Old_age Always - 25 (Min/Max 22/31) 194 Temperature_Celsius 0x0022 025 039 000 Old_age Always - 25 (0 22 0 0 0) 195 Hardware_ECC_Recovered 0x001a 064 057 000 Old_age Always - 155109699 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0000 100 253 000 Old_age Offline - 0 202 Data_Address_Mark_Errs 0x0032 100 253 000 Old_age Always - 0

SMART Error Log Version: 1 No Errors Logged

SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error

  1. 1 Extended offline Completed without error 00% 13097 -
  2. 2 Extended offline Completed without error 00% 4345 -
  3. 3 Short offline Completed without error 00% 0 -

SMART Selective self-test log data structure revision number 1

SPAN  MIN_LBA  MAX_LBA  CURRENT_TEST_STATUS
   1        0        0  Not_testing
   2        0        0  Not_testing
   3        0        0  Not_testing
   4        0        0  Not_testing
   5        0        0  Not_testing

Selective self-test flags (0x0):

 After scanning selected spans, do NOT read-scan remainder of disk.

If Selective self-test is pending on power-up, resume after 0 minute delay.

So /dev/sda has failed.

Here are the steps:

Take note of the GOOD disk serial number so I leave that one in when I replace it: Serial Number: 9RA6DZP8

Mark and remove failed disk from raid:

[root@myServer ~]# mdadm --manage /dev/md0 --fail /dev/sda1 mdadm: set /dev/sda1 faulty in /dev/md0

[root@myServer ~]# mdadm --manage /dev/md1 --fail /dev/sda2 mdadm: set /dev/sda2 faulty in /dev/md1

[root@myServer ~]# mdadm --manage /dev/md2 --fail /dev/sda3 mdadm: set /dev/sda3 faulty in /dev/md2

[root@myServer ~]# mdadm --manage /dev/md0 --remove /dev/sda1 mdadm: hot removed /dev/sda1

[root@myServer ~]# mdadm --manage /dev/md1 --remove /dev/sda2 mdadm: hot removed /dev/sda2

[root@myServer ~]# mdadm --manage /dev/md2 --remove /dev/sda3 mdadm: hot removed /dev/sda3

Make sure grub is installed on the good disk and that grub.conf is updated:


[root@myServer ~]# grub-install /dev/sdb Installation finished. No error reported. This is the contents of the device map /boot/grub/device.map. Check if this is correct or not. If any of the lines is incorrect, fix it and re-run the script `grub-install'.

  1. this device map was generated by anaconda

(hd0) /dev/sda (hd1) /dev/sdb

Take note of the which hd partition corresponds with the good disk, ie hd1 in this case.

[root@myServer ~]# vim /boot/grub/menu.lst

Add fallback=1 right after default=0 Go to the bottom section where you should find some kernel stanzas. Copy the first of them and paste the stanza before the first existing stanza; replace root (hd0,0) with root (hd1,0) Should look like this:

[...] title CentOS (2.6.18-128.el5)

       root (hd1,0)
       kernel /vmlinuz-2.6.18-128.el5 ro root=/dev/VolGroup00/LogVol00
       initrd /initrd-2.6.18-128.el5.img

title CentOS (2.6.18-128.el5)

       root (hd0,0)
       kernel /vmlinuz-2.6.18-128.el5 ro root=/dev/
       initrd /initrd-2.6.18-128.el5.img

Save and quit

[root@myServer ~]# mv /boot/initramfs-$(uname -r).img /boot/initramfs-$(uname -r).img.bak

[root@myServer ~]# mkinitrd /boot/initramfs-$(uname -r).img $(uname -r)

[root@myServer ~]# init 0

Swap the bad drive with the new drive and boot the machine.

Once it's booted:

Check the device names with cat /proc/mdstat and/or fisk -l. The newly installed drive on myServer was named /dev/sda

[root@myServer ~]# modeprobe raid1

[root@myServer ~]# modeprobe linear

[root@myServer ~]# sfdisk -d /dev/sdb | sfdisk --force /dev/sda

[root@myServer ~]# sfdisk -l => sanity check

[root@myServer ~]# mdadm --manage /dev/md0 --add /dev/sda1 mdadm: added /dev/sda1

[root@myServer ~]# mdadm --manage /dev/md1 --add /dev/sda2 mdadm: added /dev/sda2

[root@myServer ~]# mdadm --manage /dev/md2 --add /dev/sda3 mdadm: added /dev/sda3

[root@myServer ~]# cat /proc/mdstat => Sanity check Personalities : [raid1] [linear] md0 : active raid1 sda1[1] sdb1[0]

     128384 blocks [2/2] [UU]
     

md1 : active raid1 sda2[2] sdb2[0]

     16779776 blocks [2/1] [U_]
     [>....................]  recovery =  3.2% (548864/16779776) finish=8.8min speed=30492K/sec
     

md2 : active raid1 sda3[2] sdb3[0]

     139379840 blocks [2/1] [U_]
     	resync=DELAYED
     

unused devices: <none>


That's it! :)